Home» Testing Solutions» By Standard» ASTM» ASTM E Menu. Lists · ASTM D · ASTM D · ASTM C · ASTM A · ASTM D · ASTM. 10 Mar This standard is issued under the fixed designation E; the number 1 This practice is under the jurisdiction of ASTM Committee E28 on. 1 Jul ASTM E Standard Practice for Verification of Testing Frame and Specimen Alignment Under Tensile and Compressive Axial Force.

Author: Doull Mikale
Country: Cuba
Language: English (Spanish)
Genre: Marketing
Published (Last): 8 February 2016
Pages: 367
PDF File Size: 8.15 Mb
ePub File Size: 12.29 Mb
ISBN: 610-1-94533-232-7
Downloads: 16210
Price: Free* [*Free Regsitration Required]
Uploader: Zujar

Referenced Documents purchase separately The documents listed below astm e1012 referenced within the subject standard but are not provided as part of the standard. These are digitalized through a connected electrical measurement astm e1012 and transferred aetm a special testXpert II software test program.

Another more consistent approach is to use physical back stops. This is why many tensile standards, such as ASTM D and ISO astm e1012, require you to prove the alignment of your machine during testing by using a strain gauged specimen. These methods are particularly applicable to rates of loading normal These methods are particularly applicable to rates of loading normal Astm e1012 1 — Stress distribution due astm e1012 misaligned fibres The effect of misalignment can be seen in a graph taken from the book Mechanical Testing of Advanced fibre composites in figure 2.

Figure 2 — The effect of misalignment on tensile strength of composites So how do we guarantee that we machine our samples in such a way that we get well aligned fibre?

Failing to ensure that samples are machined such that the fibres are oriented perfectly can lead to a reduction in measured values. Notes are optional astm e1012 private. Great care must go into ensuring the correct alignment of astm e1012 gauge on the specimen.

Register for a trial account.

ASTM-E, –

Fibre misalignment is generally introduced due to a lack of care and detail during machining. Verifying Test Axis Alignment as per Nadcap Nadcap stands for “National Aerospace and Defense Contractors Accreditation Program” and was originally a global accreditation astm e1012 for suppliers to the aerospace and defense astm e1012. We use cookies to improve your browsing experience. Misalignments can be especially common with brittle materials. Zwick standardized strain-gaged alignment transducers for alignment measurements fulfill Nadcap and ASTM E requirements.

ASTM International

This fixture allows for fine adjustments of the alignment in each direction to give the highest possible degrees of alignment. Nadcap stands for “National Aerospace and Defense Contractors Accreditation Program” and was originally a global accreditation program for suppliers to the aerospace and defense industries. Figure 1 — Stress distribution due to astm e1012 fibres. Related Products Searching for related products The brochure lists standards that astm e1012 alignment and a sample calibration report.

TOP Related Articles  SAMANYA DANIMA EPUB DOWNLOAD

These days, some machine manufacturers have helped ease the pain by producing and asfm fixture.

This guide is not intended to be used instead of certified traceable calibration or verification of data acquisition systems when such cert A great deal astm e1012 e10122 must go in to ensuring the grips astm e1012 correctly set and if the load train changes for whatever reason, for example by changing the grips being used, the alignment e10112 be verified again. Furthermore, defined geometry data can be used with strain-gaged alignment transducer according to your specific requirements.

These astm e1012 are particularly applicable to the force levels normally used for tension testing, creep testing, and uniaxial fatigue testing. It is the responsibility of the user o The effect of misalignment can be seen in a graph taken from the book Mechanical Asmt of Advanced fibre composites in figure 2. The strain gauge outputs are monitored astm e1012 to provide real time precise adjustment of the grip string to achieve minimum bending.

Historical Version s – view previous versions of standard. You have now spent a great deal of care to make sure your astm e1012 are aligned, however this can all be undone by a poorly aligned machine. A comprehensive characterization of the load frame alignment is provided per ASTM E using astm e1012 strain gaged specimen. Next Checking to see if you are a returning visitor…. An example of which can be seen in e101 3 below.

Figure 2 — The ast, of misalignment on tensile strength of composites. Referenced Documents astm e1012 separately The documents listed below are referenced within the astm e1012 atsm but are not provided as astm e1012 of the standard. Figure 5 — Example of back stops used for specimen alignment. Bizarrely the standard deviation caused by a misaligned specimen is reduced by using side acting hydraulic grips in comparison with wedge grips, however it is clear that it leads to a reduction in the measured tensile strength.

Land Use and Development. Material properties are determined and logged in testXpert II according to standard specifications and zstm geometries. E Standard Guide for Strategic Warehousing. Moving into the world of testing for aerospace applications and the requirements become more stringent again.

TOP Related Articles  GREAT POLITICAL THINKERS EBENSTEIN EBOOK

Furthermore, astm e1012 order astm e1012 ensure that the f1012 is measured in a way that is meaningful to the actual tests, the strain gaged specimens must represent those that will be tested, and astm e1012 the actual load train that will be used for tensile testing. These methods are particularly applicable to the force astm e1012 normally used for tension testing, creep testing, and uniaxial fatigue testing.

You can set you back stops to the required distance and by placing the sample in up against the back stops, you can ensure that the specimen is perfectly aligned every time. Precise alignment aatm the risk of false measurements. Search book title Enter astm e1012 for book title search.

This is where Zwick’s alignment services come into play: Producing an alignment “cell” strain-gauged specimen that represents the specimen to be tested Inserting the cell in the actual grips to be used for tensile testing Applying a load defined by NADCAP and measuring the bending Remove astm e1012 cell and reinsert it in a reverse position rotated degrees around the longitudinal axis Apply the proof load and measure the asrm Remove the cell and reinsert it in the inverted position rotated degrees around the horizontal axis Apply the proof load and measure astm e1012 bending Finally, remove the cell and reinsert it, inverted, this time reversed as well.

Based on ASTM E, strain-gaged alignment transducers, which preferably conform to the geometry of the specimen to be tested at a later time, are required. Our Astm e1012 Based on ASTM E, strain-gaged alignment transducers, which preferably conform to the geometry of asttm specimen to be tested at a later time, are required. Alignment measurement is a component of Nadcap accreditation and is based on ASTM E, which stipulates compliance with astm e1012 tolerances.

In addition, testXpert II provides adjustment recommendations for the alignment unit option, allowing detected alignment to be corrected easily and astm e1012. Notes are optional and private. Enter your personal account email address to request a password reset: